AVEIR™ LEADLESS
PACEMAKERS
The only leadless solutions that can provide therapy
for all common pacemaker indications1,2,3
AVEIR™ LEADLESS PACEMAKERS (LPs) ARE THE ONLY LEADLESS SOLUTIONS THAT CAN PROVIDE THERAPY FOR ALL COMMON PACEMAKER INDICATIONS1,2,3
AVEIR™ AR ATRIAL LP

- Sinus node dysfunction (SND) and normal atrioventricular (AV) and intraventricular conduction systems
AVEIR™ VR VENTRICULAR LP

- Significant bradycardia and normal sinus rhythm with only rare episodes of AV block or sinus arrest
- Chronic atrial fibrillation
AVEIR™ DR DUAL CHAMBER LP SYSTEM

- Sick sinus syndrome
- Chronic, symptomatic 2nd- and 3rd- degree AV block
- Symptomatic bilateral bundle-branch block when tachyarrhythmia and other causes have been ruled out
FIND OUT MORE ABOUT:
Patients considerations of SND / AV BLOCK with AVEIR LPs

Patient therapy can be tailored by implanting an atrial or ventricular device alone, or both combined, for dual-chamber support. The option to upgrade over time allows you to meet your patients’ needs today and adapt to common disease progression to meet your patients’ needs in the future.

ONE IN FOUR HEART BLOCK PATIENTS NEEDS ATRIAL PACING17
In a 381-patient study, at 3 years post-pacemaker implant:

38% of incomplete heart block patients had a clinically significant atrial pacing need*

25% of complete heart block patients had a clinically significant atrial pacing need*



PROPORTIONS OF PATIENTS WITH PACING BURDEN ABOVE RELEVANT CUT-OFF VALUES AT 3 AND 6 YEARS POST-IMPLANTATION
| AT 3 YEARS | AT 6 YEARS | |||
|---|---|---|---|---|
| >20% AP | >40% AP | >20% AP | >40% AP | |
| Incomplete AVB | 38% | 20% | 43% | 63% |
| Complete AVB | 25% | 10% | 29% | 78% |
TV
TV
- AVEIR™ Leadless Pacemakers and Delivery Catheter IFU. ARTEN600361108.
- Micra‡ VR2 MC2VR01 IFU.
- Micra‡ AV2 MC2AVR1 IFU.
- Udo EO, Zuithoff NP, van Hemel NM, et al. Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study. Heart Rhythm. 2012;9(5):728-35. doi: 10.1016/j.hrthm.2011.12.014.
- Cantillon DJ, Exner DV, Badie N, et al. Complications and Health Care Costs Associated With Transvenous Cardiac Pacemakers in a Nationwide Assessment. JACC Clin Electrophysiol. 2017;3(11):1296-1305. doi: 10.1016/j.jacep.2017.05.007.
- AVEIR Leadless Pacemakers and Delivery Catheter IFU. ARTEN600307044. ARTEN600350965.
- Cha YM, El-Chami MF, Liu CF, et al. 2026 HRS/AHA/APHRS/EHRA/IDSA/LAHRS/PACES/STS expert consensus statement update on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2026;S1547-5271(26)02264-2. doi: 10.1016/j.hrthm.2026.04.015.
- Boersma LV, El‑Chami M, Steinwender C, et al. Practical considerations, indications, and future perspectives for leadless and extravascular cardiac implantable electronic devices: a position paper by EHRA/HRS/LAHRS/APHRS. Europace. 2022;24(10):1691‑1708. doi:10.1093/europace/euac066.
- National Institute for Health and Care Excellence (NICE). Leadless cardiac pacemaker implantation for bradyarrhythmias. Health Technology Guidance HTG770. Feb 25, 2026. Accessed June 16, 2026. https://www.nice.org.uk/guidance/htg770.
- AVEIR Leadless Pacemakers and Delivery Catheter IFU. ARTEN600175957; ARTEN600307044; ARTEN600361109.
- Nilsson KR Jr, Birgersdotter-Green U, Saleem-Talib S, et al. Leadless atrial versus transvenous pacing for sinus node dysfunction: 1-year outcomes from the leadless ARRIVE real-world study. Europace. 2026;28(4):euag072. doi: 10.1093/europace/euag072.
- Ip JE, Brady PA, Kroman AM, et al. Leadless Versus Transvenous Single-Chamber Ventricular Pacemakers: Real-World Evidence From AVEIR™ VR Coverage With Evidence Development Study. J Am Heart Assoc. 2025;14(21):e042471. doi: 10.1161/JAHA. 125.042471.
- Lo M, Amin AK, Kowalski M, et al. Leadless Versus Transvenous Dual-Chamber Pacemakers: Real-World Evidence From AVEIR DR Coverage With Evidence Development Study. J Cardiovasc Electrophysiol. 2026;37(3):544-553. doi: 10.1111/jce.70255.
- Neuzil P, Exner DV, Knops RE, et al. Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers. J Am Coll Cardiol. 2025;85(11):1111-1120. doi: 10.1016/j.jacc.2024.10.094.
- Glikson M, Nielsen JC, Kronborg MB, et al. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427-3520. doi: 10.1093/eurheartj/ehab364. Erratum in: Eur Heart J. 2022 May 1;43(17):1651. doi: 10.1093/eurheartj/ehac075.
- Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society. J Am Coll Cardiol. 2019;74(7):932-987. doi: 10.1016/j.jacc.2018.10.043. Erratum in: J Am Coll Cardiol. 2019;74(7):1014-1016. doi: 10.1016/j.jacc.2019.06.046.
- Breeman KTN, Dijkshoorn LA, Wilde AAM, et al. Predicted Need for Atrial and Ventricular Pacing Per Indication Group in Patients With Dual-Chamber Pacemakers. Heart Lung Circ. 2023;32(5):629-637. doi: 10.1016/j.hlc.2023.02.007. Erratum in: Heart Lung Circ. 2024;33(2):e17. doi: 10.1016/j.hlc.2024.01.003.
- Ip JE, Cheung JW , Liu CF , et al. Maximizing battery longevity of leadless pacemaker systems by optimizing individualized programming. Heart Rhythm. 2026;23(2):e293-e294. doi: 10.1016/j.hrthm.2025.10.021.
- Vogt ML, Kellmann T, Ihara Z. Patient’s lifetime budget impact of a leadless pacemaker compared to transvenous pacemakers in France. Poster presented at: European Heart Rhythm Association; April 12-14, 2026; Paris.