PIONEERING INNOVATION IN LBBAP
Experience the innovation of the UltiPace™ Pacing Lead, Abbott's latest lead for left bundle branch area pacing (LBBAP) with a robust distal lead tip design.* Engineered for superior performance in the pursuit of continuous innovation.1


RESISTANT TO DISTAL FATIGUE FAILURE
UltiPace™ Pacing Leads have a robust distal lead tip without a flexible zone that helps reduce stress on the conductors and the chance for distal fatigue failure compared to other leads.2

The Helix Locking Tool is a proven solution to lock an extended helix during tissue burrowing without retraction.2

The Helix Locking Tool aids with lead fixation by providing control over the extension and retraction of the helix.
CONTINUOUS UNIPOLAR PACING AND IMPEDANCE MONITORING
Provides the user with uninterrupted feedback to help achieve optimal results.3

Improvement in torsional stiffness when using UltiPace™ Pacing Leads compared to LBBAP approved lumenless pacing leads.2

Torque being applied to UltiPace™ Pacing Lead body in LBBAP procedure.
The CPS Locator™ 3D Delivery Catheter is a single-use percutaneous catheter intended to introduce pacing leads. It accommodates 6F stylet-driven leads, such as the UltiPace™ Pacing Lead, and provides better support with less risk of kinking.3

PROVEN SUCCESS
Demonstrated high success rate in LBBAP procedures.4
ACCOMMODATING SOLUTIONS
Three unique distal curves and two lengths provide enhanced variability and reach to accommodate various patient anatomy needs.5
ADDITIONAL PRODUCT FEATURES
- Each catheter is equipped with a hemostatic valve, and the distal tip is radiopaque to facilitate imaging under fluoroscopy
- The Agilis HisPro™ Slitter is an accessory designed to ensure alignment and protect the lead during catheter slitting
- Designed to accommodate a 6F lead with a recommended minimum length of 58 cm for the 42 cm catheters and 65 cm for the 45 cm catheters6
- The catheter has an inner diameter of 7F, an outer diameter of 9F, and the dilator is compatible with a 0.035” guidewire
TV
TV
- Abbott. Data on File. Item: 91010074 Ver A.
- Abbott. Data on File, Engineering Technical Report. Item: 90994484 Ver D.
- Burri H, Jastrzebski M, Cano Ó, et al. EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS). Europace. 2023;25(4):1237-1248. doi: 10.1093/ europace/euad044. Erratum in: Europace. 2023 Apr 15;25(4):1520. doi: 10.1093/europace/euad098.
- Nair D, Atwater B. Implantation of a stylet-driven lead for left bundle branch area pacing guided by new delivery catheters: A two-center experience. J Arrhythmia. 2023; 39:13-268. AB-752-CIED-CRT. Available at: doi.org/10.1002/joa3.12902. Accessed June 2026.
- Abbott. Data on File. Competitive Summary. MAT-2302264 v1.0
- Abbott. Data on File. Item: 91112329.