ULTIPACE™PACING LEAD
CONDUCTION SYSTEM PACING

PIONEERING INNOVATION IN LBBAP

Experience the innovation of the UltiPace™ Pacing Lead, Abbott's latest lead for left bundle branch area pacing (LBBAP) with a robust distal lead tip design.* Engineered for superior performance in the pursuit of continuous innovation.1

*Robust distal lead tip without a flexible zone in distal 14.5 mm.
 

RESISTANT TO DISTAL FATIGUE FAILURE

UltiPace™ Pacing Leads have a robust distal lead tip without a flexible zone that helps reduce stress on the conductors and the chance for distal fatigue failure compared to other leads.2

Zero helix retraction


The Helix Locking Tool is a proven solution to lock an extended helix during tissue burrowing without retraction.2


The Helix Locking Tool aids with lead fixation by providing control over the extension and retraction of the helix.

Improved torque transmission with fewer rotations

CONTINUOUS UNIPOLAR PACING AND IMPEDANCE MONITORING

Provides the user with uninterrupted feedback to help achieve optimal results.3


Improvement in torsional stiffness when using UltiPace™ Pacing Leads compared to LBBAP approved lumenless pacing leads.2


Torque being applied to UltiPace™ Pacing Lead body in LBBAP procedure.

CPS Locator™ 3D Catheters

The CPS Locator™ 3D Delivery Catheter is a single-use percutaneous catheter intended to introduce pacing leads. It accommodates 6F stylet-driven leads, such as the UltiPace™ Pacing Lead, and provides better support with less risk of kinking.3

PROVEN SUCCESS

Demonstrated high success rate in LBBAP procedures.4

ACCOMMODATING SOLUTIONS

Three unique distal curves and two lengths provide enhanced variability and reach to accommodate various patient anatomy needs.5

ADDITIONAL PRODUCT FEATURES

  • Each catheter is equipped with a hemostatic valve, and the distal tip is radiopaque to facilitate imaging under fluoroscopy 
  • The Agilis HisPro™ Slitter is an accessory designed to ensure alignment and protect the lead during catheter slitting 
  • Designed to accommodate a 6F lead with a recommended minimum length of 58 cm for the 42 cm catheters and 65 cm for the 45 cm catheters6 
  • The catheter has an inner diameter of 7F, an outer diameter of 9F, and the dilator is compatible with a 0.035” guidewire
Connext
TV

CONNECT TO THE LATEST
IN STRUCTURAL HEART
THERAPY

Find out more

TV

References
  1. Abbott. Data on File. Item: 91010074 Ver A. 
  2. Abbott. Data on File, Engineering Technical Report. Item: 90994484 Ver D.
  3. Burri H, Jastrzebski M, Cano Ó, et al. EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS). Europace. 2023;25(4):1237-1248. doi: 10.1093/ europace/euad044. Erratum in: Europace. 2023 Apr 15;25(4):1520. doi: 10.1093/europace/euad098. 
  4. Nair D, Atwater B. Implantation of a stylet-driven lead for left bundle branch area pacing guided by new delivery catheters: A two-center experience. J Arrhythmia. 2023; 39:13-268. AB-752-CIED-CRT. Available at: doi.org/10.1002/joa3.12902. Accessed June 2026. 
  5. Abbott. Data on File. Competitive Summary. MAT-2302264 v1.0 
  6. Abbott. Data on File. Item: 91112329.

© Abbott 2026. All rights reserved. MAT-2676034 v1.0

You are about to leave my-connext.com

You are now leaving my-connext.com. Abbott is not responsible for any content published on the third-party website you are about to enter. Abbott has not reviewed and does not endorse any information presented on third-party websites.

The content on this website is intended for healthcare professionals in EMEA with applicable health authority product registrations, excepted those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011 article 34. Click OK to confirm you are a healthcare professional to proceed.

OK Decline