VALVE SOLUTIONS
MECHANICAL HEART VALVES (MHV)
The Abbott portfolio of surgical mitral valves includes stented tissue valves, mechanical valves, and annuloplasty rings that are designed to rebuild healthier hearts.
MECHANICAL HEART VALVES (MHV)
Unique design features have established Abbott mechanical heart valves—including the Masters™ Series—as a gold standard for reliability and performance, while maintaining low complication rates over the long term.
CONFIDENTLY IMPLANT THE MOST TRUSTED MITRAL MECHANICAL VALVES IN THE WORLD


FIND OUT MORE ABOUT:
Abbott mechanical heart valves lead the way with a proven bileaflet design that results in low thrombogenicity and excellent patient outcomes.
- Leaflets open to an 85-degree angle in systole due to their upstream positioning, enabled by unique pivot guards (shown at right)
- Strong, uniform velocities within hinge recesses aid washout of blood elements3
- Low carbon surface area means less thrombus formation
- Orifice-to-annulus ratio (as high as 84%) ensures large effective orifice areas (EOAs) and reduces prosthesis-patient mismatch4

THE PIVOT GUARD DESIGN | AN ABBOTT HALLMARK
Featured in all Abbott Mechanical Heart Valves, the Pivot Guard offers benefits both during implant and post-implant
- Recessed design minimizes interaction with sub-annular native mitral valve apparatus
- Minimized carbon surface area can lessen thrombus formation
- Pivot guards help shield pivot mechanism from pannus ingrowth
- Enables a consistent 85-degree opening angle, promoting minimized leaflet flutter and more laminar flow through the orifice5

LOW THROMBOGENICITY | A NECESSITY IN MHV REPLACEMENTS
Designed with Low Thrombogenicity at the Forefront
- Large internal diameters up to 26.1 mm available promote low pressure gradients6
- Low gradients can help minimize shear stress and thrombogenicity7
- Uniform velocities within hinge recesses help aid washout of blood elements3
- Abbott hinge design enables complete leaflet sweep, further aiding washout
- Abbott hinge design enables complete leaflet sweep, further aiding washout

ABBOTT MECHANICAL HEART VALVES:
A GOLD STANDARD
TV
TV
- Internal Sales Tracking Spreadsheet. Data on file at Abbott.
- MHV Paper List. Data on file at Abbott.
- Jun BH, Saikrishnan N, Yoganathan AP. Micro particle image velocimetry measurements of steady diastolic leakage flow in the hinge of a St. Jude Medical Regent™ mechanical heart valve. Ann Biomed Eng. 2014;42(3):526-540. doi.org/10.1007/s10439-013-0919-y.
- Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol. 2000;36(4):1131-1141.
doi.org/10.1016/S0735-1097(00)00859-7. - Shipkowitz T, Ambrus J, Kurk J, et al. Evaluation technique for bileaflet mechanical valves. J Heart Valve Dis. 2002;11(2):275-282.
- Internal Design Prints. Data on file at Abbott.
- Alemu Y, Bluestein D. Flow induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. Artif Organs. 2007; 31(9):677-688.
doi.org/10.1111/j.1525-1594.2007.00446.x. - Gammie JS, Chikwe J, Badhwar V, et al. Isolated mitral valve surgery: The Society of Thoracic Surgeons Adult Cardiac Surgery Database analysis. Ann Thorac Surg. 2018;106(3):716-727.
- Masters™ Series Instructions for Use.